"Batch" mode: Download applications automatically to target systems
Creating a script file: Defining options
8
Lenze · EASY Starter (Application Loader) - "Batch"-Mode · 1.1 EN - 06/2014
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Key
Parameter
The standard setting is printed in bold. It is valid if no parameter is given.
NodeAddress
Examples
Name of the bus server and address of the target system.
• Depending on the bus system, different settings are possible.
Communication via system bus
• Note: The "SDO" parameter has to be given in addition!
• The target system has the CAN node address "11".
NodeAddress=Lenze OPC system bus server.11
Communication via diagnostic adapter
If only one diagnostic adapter is connected to the PC, the default address "0" can
be used.
NodeAddress=Lenze OPC Diagnostics Server.0
Communication via several diagnostic adapters
If several diagnostic adapters are connected to the PC, the non-ambiguous serial
number of each diagnostic adapter is required for addressing purposes.
• The serial number (S/N) is printed on the diagnostic adapter.
• In the following example, the diagnostic adapter has the serial number
"00002485".
IPNodeAddress=Lenze OPC Diagnostics Server.00002485
Communication via Ethernet NRT
• Use the default value "1" as address.
• Note: The IP address has to be given with the "IP" parameter.
NodeAddress=Lenze OPC Ethernet Server.1
Communication via Lecom
• The target system has the LECOM node address "5".
NodeAddress=Lenze OPC Lecom Server.1-5
IP
Giving the IP address of the target device.
• Note: The dots of the IP address have to be replaced by underscores,
example: 203_0_113_195 (instead of 203.0.113.195).
• The IP address only needs to be given in case of Ethernet NRT communication.
SDO
Giving the parameter channel (1 or 2) for communication.
• Data only has to be given when communicating via system bus (CAN).
• Tip: To achieve a higher performance, the same parameter channel for all
devices should be set in the script file.
• The value "0" deactivates the division into parameter channels. This serves to
use the total range of node addresses.
BinFile
Path and file name of the »Drive PLC Developer Studio« file (*.bin) for the
download.
• This option is not applicable by target systems without PLC functionality.
• The indication of the file is optional (only the files given here will be
transferred to the target system).
AddDataFile
Path and file name of the »CamDesigner« file/profile data for the download:
*.lc7 for 9300 Servo-Kurvenscheibe/*.lc9 for 9300 Servo PLC.
• This option is not applicable by target systems that do not support the
download of application data.
• The indication of the file is optional (only the files given here will be
transferred to the target system).
ParameterSetFile
Path and file name of the »Global Drive Control« parameter set file (*.gdc) for the
download.
• The indication of the file is optional (only the files given here will be
transferred to the target system).
ApplicationFileSet
Path and file name of the »L-force Loader« file (*.lfl) for the download.
• This option can be used inverters of the Inverter Drives 8400 and Servo Drives
9400 device series.