"Batch" mode: Download applications automatically to target systems

Creating a script file: Defining options

8

Lenze · EASY Starter (Application Loader) - "Batch"-Mode · 1.1 EN - 06/2014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Key

Parameter

The standard setting is printed in bold. It is valid if no parameter is given.

NodeAddress

Examples

Name of the bus server and address of the target system.

• Depending on the bus system, different settings are possible.

Communication via system bus

Note: The "SDO" parameter has to be given in addition!

• The target system has the CAN node address "11".

NodeAddress=Lenze OPC system bus server.11

Communication via diagnostic adapter

If only one diagnostic adapter is connected to the PC, the default address "0" can

be used.

NodeAddress=Lenze OPC Diagnostics Server.0

Communication via several diagnostic adapters

If several diagnostic adapters are connected to the PC, the non-ambiguous serial

number of each diagnostic adapter is required for addressing purposes.

• The serial number (S/N) is printed on the diagnostic adapter.

• In the following example, the diagnostic adapter has the serial number

"00002485".

IPNodeAddress=Lenze OPC Diagnostics Server.00002485

Communication via Ethernet NRT

• Use the default value "1" as address.

Note: The IP address has to be given with the "IP" parameter.

NodeAddress=Lenze OPC Ethernet Server.1

Communication via Lecom

• The target system has the LECOM node address "5".

NodeAddress=Lenze OPC Lecom Server.1-5

IP

Giving the IP address of the target device.

Note: The dots of the IP address have to be replaced by underscores,

example: 203_0_113_195 (instead of 203.0.113.195).

• The IP address only needs to be given in case of Ethernet NRT communication.

SDO

Giving the parameter channel (1 or 2) for communication.

• Data only has to be given when communicating via system bus (CAN).

Tip: To achieve a higher performance, the same parameter channel for all

devices should be set in the script file.

• The value "0" deactivates the division into parameter channels. This serves to

use the total range of node addresses.

BinFile

Path and file name of the »Drive PLC Developer Studio« file (*.bin) for the

download.

• This option is not applicable by target systems without PLC functionality.

• The indication of the file is optional (only the files given here will be

transferred to the target system).

AddDataFile

Path and file name of the »CamDesigner« file/profile data for the download:

*.lc7 for 9300 Servo-Kurvenscheibe/*.lc9 for 9300 Servo PLC.

• This option is not applicable by target systems that do not support the

download of application data.

• The indication of the file is optional (only the files given here will be

transferred to the target system).

ParameterSetFile

Path and file name of the »Global Drive Control« parameter set file (*.gdc) for the

download.

• The indication of the file is optional (only the files given here will be

transferred to the target system).

ApplicationFileSet

Path and file name of the »L-force Loader« file (*.lfl) for the download.

• This option can be used inverters of the Inverter Drives 8400 and Servo Drives

9400 device series.

This manual is related to the following products: