1 communication, 2 general options, 3 setting the options for the target systems – Lenze EASY Starter(Application Loader) User Manual
Page 7: Communication, General options, Setting the options for the target systems
![background image](/manuals/566302/7/background.png)
Lenze · EASY Starter (Application Loader) - "Batch"-Mode · 1.1 EN - 06/2014
7
"Batch" mode: Download applications automatically to target systems
Creating a script file: Defining options
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.3.1
Communication
Define the communication settings in the [Communication] section.
3.3.2
General options
Define the general settings in the [Common] sections.
3.3.3
Setting the options for the target systems
In the [DEVICExxx] section, the options for the prevailing target system to which you want to
download the application are defined.
• A separate [DEVICExxx] section has to be set for each target system. xxx marks the
consecutive number for the prevailing target system.
• The number of the [DEVICExxx] sections has to comply with the value of the
NumberOfDevices key in the [COMMONxxx]section.
Example: If in section [COMMON] the NumberOfDevices=3, three sections have to be added in
[DEVICE
xxx]: [DEVICE001], [DEVICE002], [DEVICE003].
• The processing order of the target systems corresponds to the ascending number order, starting
with [DEVICE001].
The following options can be defined in the [DEVICE] section:
Note!
Before being processed, a script file is not checked for correctness but processed until the
error source has been reached.
In case of an incorrect processing, use the log file to analyse and remove errors.
Key
Parameter
Baud rate
Baud rate of the system bus in [kBaud]
• Defining the baud rate in the script file is optional.
• If no baud rate is given in the script file, the value set in the system bus
configurator is used.
Key
Parameter
Standard setting = 0. Is valid if no parameter is given.
NumberOfDevices
Defining the number of target systems.
• In the [DEVICExxx] section, the respective sections have to be entered
according the number defined here.
ShowProcessing
Defines whether a status window is visible:
• 0 = do not show status window.
• 1 = show status window.
ExitAfterDownload
Activates the automatic closing of the »EASY Starter (Application Loader)«
after the script file has been processed:
• 0 = Do not close »EASY Starter (Application Loader)« after processing.
• 1 = Close »EASY Starter (Application Loader)« after processing.