Appendix
Application example
EPM−H605 with safety PLC and EVS 93xx − ES V004 servo inverter
l
107
EDBPM−H605 DE/EN/FR 7.2
Terminal assignment
Terminal
Function
Lenze setting
(printed in bold)
Level / status
Technical data
X11/K32
X11/K31
Safety relay K
SR
1st disconnection
path
Pulse inhibit feedback
Open contact: Pulse
inhibit deactivated
(operation)
Closed contact: Pulse
inhibit active
X11/33
– coil of safety relay K
SR
Coil deenergised: Pulse
inhibit active
X11/34
+ coil of safety relay K
SR
Coil energised: Pulse
inhibit deactivated
(operation)
X5/28
Controller inhibit
(DCTRL−CINH)
Controller enable and controller
inhibit
LOW: Controller
inhibited
HIGH: Controller
enabled
LOW: 0 ... +3 V
HIGH: +12 ... +30 V
Input current at
+24 V:
8 mA per input
Reading and
processing of the
input signals 1/ms
(mean value)
X5/E1
Digital inputs
(freely
assignable)
CW rotation / quick stop
deactivation
HIGH
X5/E2
CCW rotation / quick stop
deactivation
HIGH