If any malfunctions should occur during operation of the drive system, please check the
possible causes using the following table. If the fault cannot be eliminated by one of the
listed measures, please contact the Lenze Service.
Fault
Possible cause
Remedy
Drive does not turn
Voltage supply interrupted
Check connection
Faulty electrical connection
Check that supply voltage
matches nameplate data
Excessive load
Reduce load
Check drive−machine
assignment
Motor runs, gearbox does
not
Coupling components are missing or
defective
Check mounting
Gearbox is defective
Inform Lenze Service
Clutch disengaged
Engage the clutch
Unusual running noises
Overload
Reduce load
Check drive−machine
assignment
Damage to the gearbox or motor
Inform Lenze Service
Excessive temperature
Overload
Reduce load
Check drive−machine
assignment
Inadequate heat dissipation
Improve cooling air flow
Clean gearbox / motor
Lack of lubricant
Top up lubricant according to
regulations
Loose fixing elements
Vibrations
Avoid vibrations
Shrink disc connection is
spinning
¯
Correct screw tightening torque has not
been reached
– Insufficient number of passes, not all
screws are tightened correctly.
¯
Machine shaft and hollow shaft bore
not sufficiently degreased
¯
Wrong component part dimensions
– Fits, roughnesses
¯
Yield point of machine shaft material is
too low
– Re > 300 N/mm
2
required
¯
Friction factors are too low
– Coefficients of friction
m ³ 0.15
required
¯
The shrink disc itself has been
degreased so that the screws and the
bevels are dry. Due to incorrect friction
factors, the shrink disc cannot be
tightened correctly.
Specifications for assembly,
dimensions and material not
observed