Product description, Warnings – Lenze MC−xxx Card User Manual
Page 22

Product description
Variants
MC−PNC, MC−PND
l
22
BA_MC−Card EN 1.0
MC−PND (device)
I/O data
l
Configurable up to max. 1024 bytes input
l
Configurable up to max. 1024 bytes output
Communication
l
PROFINET IO−RT
– VLAN and priority tagging
– cyclic and acyclic
Functions
l
Cyclic process data
l
Acyclic read and write requests
l
Process and diagnostic alarm: 200 bytes
l
DCP
l
Context management via CLRPC
l
Generic diagnostics, channel diagnostics, extended
channel diagnostics: 200 bytes
l
Comparison of the setpoints / actual values of the
configuration
Special features
l
Maximum number of modules: 244
l
Maximum number of submodules: 1
l
No support for
– RT over UDP
– Multicast communication
l
Only one device instance is supported
¸
O
Warnings!
Use only together with appropriate cable connectors, provided with screws for
securement and secure connector to avoid loosening.
For use in controlled environment only.
¹
O
Warnings!
A utiliser exclusivement avec des connecteurs de câble à vis adaptés. Fixer les
connecteurs pour éviter toute déconnexion.
Destiné uniquement à des zones à environnement contrôlé.