Product description – Lenze MC−xxx Card User Manual
Page 17

Product description
Variants
MC−PBM, MC−PBS
l
17
BA_MC−Card EN 1.0
LED
Colour
Status
Meaning at MC−PBM
Meaning at MC−PBS
SYS
Green
On
Communication is running, the
device has at least established a
connection to one configured node
Slave is in cyclic data exchange with
DP master
Blinking with 5
Hz
No error within configuration,
communication has stopped, or
ready for communication, but no
connection to a slave
Slave has no cyclic data exchange
with DP master
Is blinking
irregularly
Start−up: No or incorrect configuration, commissioning required; runtime:
host−watchdog time error
Yellow Blinking with 1Hz
Device is in bootstraploader mode and is waiting for firmware download
Blinking with 5
Hz
Firmware download is carried out
Is blinking
irregularly
Hardware or fatal system error detected
−
Off
Supply voltage for the device is missing, or hardware is defective
ST0
−
−
No function
ST1
−
−
No function
ST2
Red
On
Device has a communication
problem with at least one
PROFIBUS−DP slave or has detected a
short circuit
Application program
(communication mode: synchronous
to bus/device−controlled) is no
longer synchronous to the bus cycle
Yellow
Is blinking
irregularly
Device is within the PROFIBUS ring
and shares the token with other
PROFIBUS master devices
−
On
Device holds the PROFIBUS token
and can transmit telegrams
Slave has received
parameter/configuration data from
the DP master and has reached the
DataExchange state
−
Off
Connection to Ethernet exists.
Slave has not reached the
DataExchange state