2 technical data, 1 general data and operating conditions, Technical data – Lenze EPM−H507 User Manual
Page 55: General data and operating conditions, 2technical data

Technical data
General data and operating conditions
2
l
55
EDBPM−H505 DE/EN/FR 6.1
2
Technical data
2.1
General data and operating conditions
General data
Conformity and approval
Conformity
CE
2004/108/EC
EMC Directive
Approval
UL
cULus
Underwriter Laboratories Inc. (File no. E189179)
Protection of persons and equipment
Enclosure
IP65 (front)
EMC
Applied standards for
limit values
EN 61000−6−4
(2007)
Noise emission. Restriction of use: Protection
requirements are not ensured in residential areas.
EN 61000−6−2
(2005)
Noise immunity. Restriction of use: Protection
requirements are not ensured in residential areas.
Operating conditions
Ambient conditions
Climate
Storage
−20 ... +60 °C
Transport
−20 ... +60 °C
Operation
0 ... +50 °C
Humidity
<85 %, without condensation
Mounting conditions
Weight
1.4 kg