beautypg.com

Rated data, Technical data – Lenze EZN3A0055H045U User Manual

Page 36

background image

Technical data

Rated data

2

l

36

EDKZN3B045 DE/EN/FR 3.0

2.2

Rated data

Mains

Voltage

Voltage range

Frequency range

U

Lrated

[V]

U

Lrated

[V]

f [Hz]

3/PE AC

400

320 − 0 % ... 440 + 0 %

45 − 0 % ... 65 + 0 %

3/PE AC

480

432 − 0 % ... 528 + 0 %

45 − 0 % ... 65 + 0 %

Type

Voltage

Frequency

Current [A]

Number

of phases

[V]

[Hz]

up to +40 °C

 up to +55 °C 

EZ...0120H012

400/480

50/60

12

7.5

3

EZ...0088H024

400/480

50/60

24

15

3

EZ...0055H045

400/480

50/60

45

28.1

3

EZ...0055H045U

 Temperature in the control cabinet

Power loss

Inductance

Voltage drop

P

loss

[W]

L [mH]

DU [V]

EZ...0120H012

50

1.20

4.5

EZ...0088H024

95

0.88

6.6

EZ...0055H045

190

0.55

13.5

EZ...0055H045U

185

0.55

13.5

This manual is related to the following products: