3 mechanical installation, 1 important notes, Mechanical installation – Lenze ECSDKxxx User Manual
Page 47: Important notes

Mechanical installation
Important notes
3
l
47
EDKCSDK002 DE/EN/FR 1.1
3
Mechanical installation
3.1
Important notes
ƒ
Capacitor modules of series ECS feature enclosure IP20 and, for this reason,
are intended for installation in control cabinets.
ƒ
If the cooling air contains air pollutants (dust, fluff, grease, aggressive gases):
–
Take suitable preventive measures , e.g. separate air duct, installation of
filters, regular cleaning.
ƒ
Possible mounting positions
–
Vertical on the mounting plate
–
DC−bus connections (X23) at the top
–
Connection for short−circuiting of the charging current limitation (X26) at
the bottom
ƒ
Maintain the specified free spaces above and below to other installations!
–
An additional free space is required if the shield assembly set
ECSZS000X0B001 is used.
–
Ensure unimpeded ventilation of cooling air and outlet of exhaust air.
–
You can install several modules of series ECS next to each other without
any clearance in a control cabinet.
ƒ
The mounting plate of the control cabinet must be electrically conductive.
ƒ
In case of continuous vibrations or shocks use shock absorbers.