2 rated data, Rated data, Technical data – Lenze ECSDKxxx User Manual
Page 46
Technical data
Rated data
l
46
EDKCSDK002 DE/EN/FR 1.1
General electrical data
EMC
Compliance with EN 61800−3
Noise emission
Compliance with limit value class A to EN 55011
(achieved with application−specific collective filter)
Noise immunity
Requirements to EN 61800−3
Requirements
Standard
Severity
ESD
1)
EN 61000−4−2
3, i. e.
l
8 kV with air discharge
l
6 kV with contact
discharge
High frequency in cables
EN 61000−4−6
10 V; 0.15 ... 80 MHz
RF interference
(enclosure)
EN 61000−4−3
3, i. e. 10 V/m;
80 ... 1000 MHz
Burst
EN 61000−4−4
3/4, i. e. 2 kV/5 kHz
Surge (on mains cable)
EN 61000−4−5
3, i. e. 1.2/50
ms
l
1 kV phase−phase
l
2 kV phase PE
Insulation resistance
Overvoltage category III to VDE 0110
Discharge current against PE (to EN 50178)
> 3.5 mA AC for operation with corresponding controllers
Enclosure
l
IP20 for standard mounting
l
IP20 for mounting in cold−plate technique
l
IP20 for mounting in push−through technique; IP54 on the heatsink
side
Protective insulation of control circuits
Safe disconnection from supply: Double/reinforced insulation to
EN 50178;
Rated insulation voltage 300 V x
√2
1)
Noise immunity in the above−mentioned severities must be guaranteed through the
control cabinet! The user must check the compliance with the severities!
2.2
Rated data
,
The most important rated data are located on the nameplate of the
device. Additional data can be found in the detailed documentation.