Potentiometer unit - installation, Connection at the standard i/o, Connection at the application i/o – Lenze E82ZBS020 User Manual
Page 9: Terminal assignment, Switch position, Off on off off, Parameterization c0034, Wiring input 1u, Jumper position, Remove jumper a

Potentiometer unit - Installation
EDK82ZBX020 3.0
l
- 3 -
Connection at the Standard I/O
STANDARD
S
7
62
8
9
7 20 28 E1
59
E2 E3 E4
A1
39
1 2 3 4 5
ON
Terminal assignment
STANDARD
S
7
62
8
9
7 20 28 E1
59
E2 E3 E4
A1
39
1 2 3 4 5
ON
>100k
GND1
X3/8:
X3/9:
X3/7:
White wire
Green wire
Brown wire
STANDARD
S
7
62
8
9
7 20 28 E1
59
E2 E3 E4
A1
39
1 2 3 4 5
ON
8 9
X3
+5V
Switch position
STANDARD
S
7
62
8
9
7 20 28 E1
59
E2 E3 E4
A1
39
1 2 3 4 5
ON
8 9
X3
7
1
2
3
4
5
STANDARD
S
7
62
8
9
7 20 28 E1
59
E2 E3 E4
A1
39
1 2 3 4 5
ON
10k
OFF
OFF
ON
OFF OFF
STANDARD
S
7
62
8
9
7 20 28 E1
59
E2 E3 E4
A1
39
1 2 3 4 5
ON
10k
E82ZAFS010
1 2 3 4 5
ON
E82ZDET001
STANDARD
S
7
62
8
9
7 20 28 E1
59
E2 E3 E4
A1
39
1 2 3 4 5
ON
Parameterization C0034
STANDARD
S
7
62
8
9
7 20 28 E1
59
E2 E3 E4
A1
39
1 2 3 4 5
ON
E82ZAFS001
Potentiometer unit
C0034 = -0-
Connection at the Application I/O
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
Wiring input 1U
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
X3/1U:
X3/9:
X3/7:
White wire
Green wire
Brown wire
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
Jumper position
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
Remove
jumper A
E82ZDET001
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
E82ZAFA011
Parameterization C0034
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
E82ZAFA011
C0034/1 = -0-
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
Wiring input 2U
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
E82ZAFA004
X3/2U:
X3/9:
X3/7:
White wire
Green wire
Brown wire
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
Jumper position
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
Remove
jumper B
E82ZDET001
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
E82ZAFA012
Parameterization C0034
A2
A1
7
7 A4 59 20 28 E1 E2 E3 E4 E5 E6
1U 1I 2U
10
9
8
7
2
1
4
3
6
5
2I 62 63 9
APPLICATION
A
1
2
3
4
5
6
7
8
9
10
A
B
C
D
Potentiometer unit
C0034/2 = -0-
Show/Hide Bookmarks