Codes – Lenze E82ZAFPC010 User Manual
Page 79

Codes
Diagnostics codes
l
79
EDS82ZAFPC010 EN 4.0
C1520: Display of all words to master
Code
Subcode
Index
Possible settings
Data type
Lenze
Selection
C1520
23055
d
=
5A0F
h
g
0
[1]
65535 U16
1 (PIW1)
...
10 (PIW10)
Display of the master’s process data input words PIW1 ... PIW10 in the different subcodes.
All words are displayed. Only the configured words are valid.
The assignment of the bit status information or the actual controller values to the up to 10
process data input words (PIW) of the master can be freely configured via code C1510.
C1521: Display of all words from master
Code
Subcode
Index
Possible settings
Data type
Lenze
Selection
C1521
23054
d
=
5A0E
h
g
0
[1]
65535 U16
1 (POW1)
...
10 (POW10)
Display of the master’s process data output words POW1 ... POW10 in the different
subcodes. All words are displayed. Only the configured words are valid.
The assignment of the up to 10 process data output words (POW) of the master to bit
control commands or controller setpoints can be freely configured via code C1511.
C1522: Display of all process data words to standard device
Code
Subcode
Index
Possible settings
Data type
Lenze
Selection
C1522
23053
d
=
5A0D
h
g
0
[1]
65535 U16
1
...
16
Display of the process data words 1 ... 16 which are transferred from the function module
to the standard device: