C1513: Monitoring response time of PZD communication
Code
Subcode
Index
Possible settings
Data type
Lenze
Selection
C1513
23062
d
=
5A16
h
3000
0
[1 ms]
65535 FIX32
The value of the response monitoring time is provided by the master.
)
Note!
A change in the monitoring time becomes effective immediately.
Monitoring starts with the receipt of the first telegram.
The setting C1513 = 0 deactivates the monitoring function.
C1514: Monitoring reaction in case of PZD communication fault
Code
Subcode
Index
Possible settings
Data type
Lenze
Selection
C1514
23061
d
=
5A15
h
0
0
[1]
3 FIX32
0: no action
1: TRIP (fault)
2: controller inhibit (CINH)
3: quick stop (QSP)
If the master does not send a message within the response monitoring time (configurable
in C1513), the action set in this code is executed.
)
Note!
A change in the monitoring reaction becomes effective immediately.