Codes – Lenze E82ZAFPC010 User Manual
Page 74

Codes
Communication−relevant Lenze codes
l
74
EDS82ZAFPC010 EN 4.0
C1512: Enable process output data
Code
Subcode
Index
Possible settings
Data type
Lenze
Selection
C1512**
23063
d
=
5A17
h
1
1
[1]
65535 FIX32
If code C1511 is changed, the process output data are automatically inhibited to ensure
data consistency.
Code C1512 can be used to re−enable all or individual process data output words (POW).
Due to the different decimal values of the bit positions, any combination of process data
output words can be enabled.
ƒ
0 = Inhibit output word
ƒ
1 = Enable output word
Value of bit position
POW 10
POW 9
...
POW 2
POW 1
2
9
2
8
2
1
2
0
65535 (FFFF
hex
) in code C1512 enables all process output data.
)
Note!
8200 vector
With 8200 vector it is not possible to enable individual process data output
words. After mains switching this code is reset to 65535. Therefore, all process
data are enabled.