Electrical installation
Important notes
l
46
EDK94ZMR47XDB DE/EN/FR/ES/IT 4.0
{
Danger!
Hazardous electrical voltage
The leakage current to earth (PE) is > 3.5 mA AC or > 10 mA DC.
Possible consequences:
ƒ
Death or severe injuries when touching the device in the event of an error.
Protective measures:
Implement the measures required in EN 61800−5−1. Especially:
ƒ
Fixed installation
– Implement PE connection in compliance with standards.
– Connect PE conductor twice or PE conductor cross−section
³ 10 mm
2
.
ƒ
Connection with a connector for industrial applications according to
IEC 60309 (CEE):
– PE conductor cross−section
³ 2.5 mm
2
as part of a multi−core supply cable.
– Provide for suitable strain relief.
(
Stop!
No device protection if the mains voltage is too high
The mains input is not internally fused.
Possible consequences:
ƒ
Destruction of the device if the mains voltage is too high.
Protective measures:
ƒ
Observe the maximally permissible mains voltage.
ƒ
Fuse the device correctly on the supply side against mains fluctuations and
voltage peaks.
(
Stop!
Overtemperature
The mains filter may become hot if permissible limit values are exceeded
during operation.
Possible consequences:
ƒ
The device may be damaged or destroyed.
Protective measures:
ƒ
Wire the overtemperature disconnection with the digital DO2 output
according to circuit proposal.