beautypg.com

Bush Hog CBH80 User Manual

Page 25

background image

Troubleshooting (Continued)

Problem

Cause

Correction

Leaky valve

Paint on valve spool; sticking

(cont.)

valve spool or scored valve spool Instead, the plug and fitting should be

removed from valve body and be

reconnected, using a new O-ring. Do not

apply excessive pressure on mounting

bolts. The rods for CBH70, CBH80 should

be torqued to 14 ft/lbs for 5/16” nuts and 33

ft/lbs for 3/8” nuts. Never force spool.

Ball in anti-cavitation check

Clean anti-cavitation valve carefully, being

valve is stuck or not seating

sure that checks move freely and seat

properly.

properly, or replace cartridge.

Sticky valve spool

Paint on valve spool; sticking

Clean valve spool. Binding is usually

spool in

valve spool or scored valve

caused from an overtightened plug,

spool

mounting bolt, fitting in valve body or

tie rod bolt. If a plug or fitting in the valve

body is leaking, do not overtighten in an

effort to stop leak. This will distort body

casting and cause spools to bind. Instead,

the plug and fitting should be removed

from valve body and be reconnected,

using a new O-ring. Do not apply exces-

sive pressure on mounting bolts. The rods

for CBH70, CBH80 should be torqued to 14

ft/lbs for 5/16” nuts and 33 ft/lbs for 3/8”

nuts. Never force spool.

Bent spool

Replace with new spool section.

Foreign particles

Clean system and valve.

Misalignment of control handle

Check linkage for binding condition

linkage

Unable to push valve

Paint on valve spool; sticking

Clean valve spool. Binding is usually

spool in

valve spool or scored valve

caused from an overtightened plug,

spool

mounting bolt, fitting in valve body or

tie rod bolt. If a plug or fitting in the valve

body is leaking, do not overtighten in an

effort to stop leak. This will distort body

casting and cause spools to bind. Instead,

the plug and fitting should be removed

from valve body and be reconnected,

using a new O-ring. Do not apply exces-

sive pressure on mounting bolts. The rods

for CBH70, CBH80 should be torqued to 14

ft/lbs for 5/16” nuts and 33 ft/lbs for 3/8”

nuts. Never force spool.

Oil leakage past spool seal into

Remove cap. If it contains oil replace spool

spool cap

seal O-rings. Check O-ring retainer to be

sure it is flat. If it has been “belled” check

for restriction from outlet to reservoir of

valve which would cause excessive back

pressure. If supply and return lines are

reversed, pressure on low pressure / return

side of valve will cause problem.

Make sure hoses are connected correctly

at bulkhead connection on backhoe.

23