Instruction Manual – Model CF2300A Oil Burner

5

Form 6104 BCF-23-R0399

Table 2 – Air tube capacity vs. firebox pressure

Figure 2 – Air tube mounting dimensions

2304

E

D

G

T

1

F

E Insertion depth
G Air tube to inside of chamber

– 0.25" ± 0.125"

T Air tube length
D Tube diameter

Figure 1 – Min. combustion chamber dimensions

Install the burner with a 2° pitch as shown.

2305

A

L

Verify firing rate

• Refer to appliance manufacturer’s instructions (if avail-

able) for firing rate and nozzle selection. Otherwise, the
maximum recommended firing rate for the burner depends
on the length of the firing chamber and the distance from
the burner center to the chamber floor. Verify that the cham-
ber dimensions are at least as large as the minimum values
given in

Figure 1

. If the appliance dimensions are smaller

than recommended, reduce the firing rate accordingly.

Verify air tube

• The information in this section may be disregarded if the

air tube is supplied by the appliance manufacturer.

• Two tube arrangements are available –

Tube

KG

— 7.0 to 19.9 GPH per

Table 2

Tube

KS

— 10.0 to 19.9 GPH per

Table 2

• Maximum firing capacity depends on the firebox pressure.

Use

Table 2

to verify the correct air tube type for the firing

rate required. Use Tube

KS

only when Tube

KG

cannot

provide the firing rate required.

• See

Figure 2

to verify the correct air tube length and air

tube combination code.

Firing rate

Minimum dimensions

(refractory-lined)

(wet-base boilers)

A

L

A

L

5 to 10 gph

8.0"

35.0"

8.0"

40.0"

10 to 15 gph

9.0"

40.0"

9.0"

50.0"

15 to 20 gph

11.0"

55.0"

11.0"

60.0"

A.T.C. Codes

(A.T.C. = Air Tube Combination)

Tube KG

Tube KS

(Dim

T

)

(Dim

D

)

(Dim

F

)

(Dim

T

)

(Dim

D

)

(Dim

F

)

All —

6¹⁄₂

2¹⁵⁄₁₆

All —

8¹⁄₈

3¹¹⁄₁₆

6¾”

CF 66 KG

6¾”

CF 66 KS

8¾”

CF 86 KS

10¼”

CF 102 KG

11”

CF 110 KS

13¾”

CF 136 KG

14½”

CF 144 KS

17¾”

CF 176 KG

18½”

CF 184 KS

Firebox

pressure

(In. w.c.)

Tube KG

Tube KS

No reserve

air

10%

turndown

No reserve

air

10%

turndown

0.0

19.9 GPH

19.9 GPH

19.9 GPH

19.9 GPH

0.2

19.2 GPH

19.1 GPH

19.7 GPH

19.6 GPH

0.4

18.5 GPH

18.3 GPH

19.5 GPH

19.3 GPH

0.6

17.9 GPH

17.6 GPH

19.4 GPH

19.1 GPH

0.8

17.2 GPH

16.8 GPH

19.2 GPH

18.8 GPH

1.0

16.5 GPH

16.0 GPH

19.0 GPH

18.5 GPH

Note: 10% turndown indicates sufficient reserve air to reduce the CO

2

in the

flue to 90% of its value.

Note: The above ratings may vary 5% due to variations in actual job conditions.