Koolance EXT-400SL User Manual
Page 19
14
Nozzles are designed to attach tightly. If you need to remove a hose for any reason,
it may not pull off easily, even after unscrewing the compression fi tting.
Usually, a connection will come free by squeezing the hose on top of the nozzle
and pulling away. If this fails, cutting a small incision lengthwise (parallel) along the
nozzle should free it.
When a hose screw has been removed, it may have distorted the tubing beneath it.
This last portion (about 1cm, 7/16”) should be trimmed to ensure a perfect fi t with
the next connection.
The tip should always be re-cut if you needed to remove the tubing with an
incision.
Connecting Exos-LT Systems
Disconnecting Hoses