Koolance CTR-CD12 User Manual
Page 4
7
Press
▼ or ▲ to change what this line will display among the options described earlier.
Press
◙
to move to line 2, and similarly use
▼ or ▲. Press
◙
again to exit.
If “CYCLIC” is chosen from the DISPLAY SET menu, multiple values will be rotated through
the front display. The first option is whether these values will cycle vertically or horizontally
through the display:
CYCLIC
VERT HORI: Rotate values vertically or horizontally
The first option, “VERT”, will flash. Press
◄ or ►
to change between these options, press
◙
to configure a selection, or press
▲ to exit.
Choosing either option with
◙
will list all
available values:
*TEMP1 21.7C : Show temperature sensor #1
*TEMP2 21.2C : Show temperature sensor #2
*TEMP3 20.8C : Show temperature sensor #3
*FAN1 1770RPM : Show fan channel #1
*FAN2 1640RPM : Show fan channel #2
*FAN3 1820RPM : Show fan channel #3
*PUMP 5730RPM : Show pump speed
*FLOW 4.1LPM: Show flow rate
The selected line will flash. Use
▼ and ▲
to navigate to other lines. Press
◙
to enable or
disable each value. This will remove the asterisk, thereby hiding that line from being shown
on the main screen:
*TEMP1 21.7C : (shown)
*TEMP2 21.2C : (shown)
*
TEMP3 20.8C : (not shown)
*FAN1 1770RPM : (shown)
*
FAN2 1640RPM : (not shown)
*
FAN3 1820RPM : (not shown)
*PUMP 5730RPM : (shown)
*FLOW 4.1LPM: (shown)
Press
◄
to return to the previous menu, or press
►
to exit DISPLAY SET.
▲
▼
▲
▼
This page is intentionally left blank.
Temperature Sensor Placement
Three surface temperature sensors are included
with this product for monitoring. Generally,
sensors are affixed to water blocks with metal tape.
(Liquid temperature sensors are also available
optionally from Koolance.)
Sensors should never be placed directly
between a heat source and its water block. This
will interfere with contact and can damage the
sensor or heat source.
Chip contact
area
(keep out)