JUMO 902434 HEATtemp Push-In RTD Temperature Probe for Heat and Cold Meter with Terminal Head for Thermowells, Type PL Data Sheet User Manual
Technical data

Data sheet 902434
Page 1/5
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone:
+49 661 6003-0
Fax:
+49 661 6003-607
E-mail:
Internet:
www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:
+44 1279 635262
E-mail:
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866
1-800-554-5866
Fax:
315-437-5860
E-mail:
Internet: www.jumousa.com
• For temperatures between 0 and 180 °C
• Approval for heat meters as replaceable temperature probes;
MID and domestic approvals
• Fulfills the requirements of DIN EN 1434, AGFW 202, and FW211
• Paired and calibrated according to the German calibration regulations
• Production certified according to module D of MID (CE and metrology identification
marking)
• Adapted accessories for installation (data sheet 902440)
• Approval for cold meter
Heat and cold meter RTD temperature probes are installed to measure temperatures in closed
pipeline systems. Thanks to insertion into thermowells with matching tolerance, emptying the
system for the regular replacement at the end of the certification period is no longer necessary.
The temperature probes are approved according to the EU directive 2004/22/EC (MID) as well
as according to the German calibration regulations (domestic approval). The temperature probes
are available in paired and calibrated versions. The officially recognized testing agency for heat
KF2 is available for this. Moreover, the production is certified according to module D of MID, and
the temperature probes are also available with the CE and metrology identification marking.
Technical data
Terminal head
Form J or B, aluminum diecast,
M16 × 1.5 or M24 × 1.5, IP65,
ambient temperature -20 to +100 °C
Process connection
Push-in RTD temperature probe
for thermowells (immersion sleeves)
Protection tube
Stainless steel, Ø 6 mm with matching tolerance
for thermowell
Measuring insert
Platinum temperature sensor according to DIN
EN 60751
Nominal value: Pt100, Pt500, Pt1000; class B
Connection: two-wire or four-wire circuit
Temperature
0 to 180 °C
Temperature difference
3 to 180 K
Minimum immersion depth
25 mm
Insertion length
85 to 400 mm
Admissible rated pressure PN
40 bar (with thermowell)
Response behavior
t
0.5
≤
10 s (installed in thermowell)
Thermoelectric voltage
≤
5 µV
Environmental conditions
Climatic 0 to 70 °C
Protection type IP65
Electromagnetic E1
Mechanical M3
Environment class C
Accessories
Thermowells, data sheet 902440
2014-04-01/00530101
Push-in RTD Temperature Probe
for Heat and Cold Meters
with Terminal Head for Thermowells (Type PL)
Heat meter
Cold meter