background image

2009-05-11/00314538

Data Sheet 90.1050 (90.1005)

Page 3/3

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14,

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow - Essex CM20 2DY, UK
Phone: +44 1279 63 55 33
Fax:

+44 1279 63 52 62

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone:

315-697-JUMO
1-800-554-JUMO

Fax:

315-697-5867

E-mail:

[email protected]

Internet: www.jumo.us

Order details:

Screw-in thermocouples with compensating cable

(1) Basic version

901050/10

Screw-in thermocouple
with fixed screw fitting

901050/20

Screw-in thermocouple
with loose screw fitting

901050/30

Screw-in thermocouple
with screw-in protection tube

(2) Operating temperature in °C / compensating cable

x x

150

-200 to +600°C / metal braiding

x x x

380

-50 to +200°C / silicone

x x x

390

-50 to +300°C / metal braiding

x x

402

-50 to +400°C / metal braiding

(3) Measuring insert

x x x

1042

1 x Fe-Con L

x x x

1043

1 x NiCr-Ni K

x x

2042

2 x Fe-Con L

x x

2043

2 x NiCr-Ni K

(4) Protection tube diameter D in mm

x x

6

6mm

x

8

8mm (M 8)

(5) Fitting length EL in mm (50

EL 500 for Type 901050/10, 901050/20)

x

17

17mm

x

25

25mm

x

37

37mm

x

100

100mm

x

137

137mm

x x

...

please specify in plain text (50mm steps)

(6) Process connection

x

104

thread 1/2"pipe

x

105

thread 3/4"pipe

x

106

thread 1"pipe

x

111

thread M 8

x

114

thread M 10 x 1

(7) Compensating cable end

x x x

03

bare cable ends

x x x

11

ferrules to DIN 46 228 Part 4 (standard)

x x x

13

receptacle 6.3 to DIN 46 247

x x x

80

multipole connector (please specify type in plain text)

(8) Compensating cable length AL in mm (500

AL 500000)

x x x

2500

2500mm

x x x

...

please specify in plain text (500mm steps)

(9) Extra codes

x x x

000

no extra code

x x x

309

uninsulated assembly (thermocouple welded to tip)

x x x

315

cable protector: coil

x x x

316

cable protector: tube

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

Order code

-

-

-

-

-

-

-

/

,...

Order example

901050/10 -

150

- 1042 -

6

-

100

-

104

-

11

- 2500 /

000

1

1. List extra codes in sequence, separated by commas.