beautypg.com

Order details – JUMO 901090 Screw-In Melt Thermocouples Data Sheet User Manual

Page 4

background image

2012-09-26/00474315

Data sheet 901090

Page 4/5

JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address:

36035 Fulda, Germany

Phone:

+49 661 6003-0

Fax:

+49 661 6003-607

E-mail:

[email protected]

Internet:

www.jumo.net

JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax:

+44 1279 635262

E-mail:

[email protected]

Internet: www.jumo.co.uk

JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone: 315-697-5866

1-800-554-JUMO

Fax:

315-697-5867

E-mail:

[email protected]

Internet: www.jumousa.com

Order details:

Screw-in melt thermocouples

(1) Basic type

901090/10

Screw-in melt thermocouples
with thermal line

901090/20

Screw-in melt thermocouples
with plug connector (LEMO device outlet ERA-2S)

901090/50

Screw-in melt thermocouples
with thermal line
and ceramic insulated probe tip

901090/60

Screw-in melt thermocouples
with plug connector (LEMO device outlet ERA-2S)
and ceramic insulated probe tip

(2) Operating temperature in °C/thermal line

x x x x

493

-40 ... +260 °C/PTFE

x x x x

505

-40 ... +400 °C/Metal braiding

x x x x

515

-40 ... +600 °C/Metal braiding

(3) Measuring insert

x x x x

1040

1× Fe-CuNi "J"

x x x x

1042

1× Fe-CuNi "L"

x x x x

1043

1× NiCr-Ni "K"

(4) Fitting length EL in mm

x x x x

152

152 mm (Standard)

x x x x

...

Specifications in plain text

(5) Probe tip shape

x x

1

Flat

x x x x

4

Blade

(6) Probe tip length L in mm

x x

0

Flat

x x x x

5

5 mm

x x x x

10

10 mm

x x x x

15

15 mm

x x x x

20

20 mm

x x x x

25

25 mm

(7) Material/surface of the probe tip

x x x x

26

1.4571 (Standard)

x x x x

39

1.4571 coating as per agreement

(8) Process connection

x x x x

126

M18 × 1.5

x x x x

153

1/2" × 20 UNF

(9) Thermal line end

x

x

00

None

x

x

03

stripped wires

x

x

11

Ferrules as per DIN 46228 Part 4 (Standard)

x

x

80

Multi-pole connector (enter type in plain text)

(10) Thermal line length AL in mm

x

x

0000

None

x

x

3000

3000 mm

x

x

...

Please specify in plain text (500 mm steps)

(11) Extra codes

x x x x

000

None

x x x x

309

uninsulated structure (element welded to the base)

x

x

315

Anti-kink spring

x

x

853

Metal protection hose on the thermal line

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

Order code

-

-

-

-

-

-

-

-

-

/

, ...

1

Order example

901090/10 -

505

-

1042

-

152

-

4

-

15

-

26

-

153

-

11

-

3000

/

315

AL

EL

L

L

EL

72

AL

EL

L

L

EL

72

1

List extra codes in sequence, separated by commas.