Admissible load at the thermowell
Thermowells 820, 876, 871, 913
The following values describe the maximum capacity of the corresponding connection type.
The maximum sealable pressure depends on the fitting conditions and may be lower.
Thermowell made of stainless steel
Thermowell made of brass
Material
Pipe and nipple: Stainless steel (1.4571)
Capacity
Temperature
Pipe diameter
8 x 0.75 mm or conical
10 x 0.75 mm
Max. allowable pressure
100 °C
92 bar
74 bar
150 °C
88 bar
71 bar
200 °C
83 bar
67 bar
300 °C
72 bar
58 bar
400 °C
67 bar
54 bar
Max. allowable
operating
temperature*
Static load +400 °C
Without load +530 °C
Observe max. allowable probe temperature of the respective thermometer version.
Material
Pipe and nipple: CuZn
Capacity
Temperature
Pipe diameter
8 x 0.75 mm
10 x 0.75 mm
Max. allowable pressure
100 °C
50 bar
40 bar
150 °C
48 bar
39 bar
Max. allowable
operating
temperature*
+150 °C