Admissible load at the thermowell

Thermowells 820, 876, 871, 913

The following values describe the maximum capacity of the corresponding connection type.
The maximum sealable pressure depends on the fitting conditions and may be lower.

Thermowell made of stainless steel

Thermowell made of brass

Material

Pipe and nipple: Stainless steel (1.4571)

Capacity

Temperature

Pipe diameter

8 x 0.75 mm or conical

10 x 0.75 mm

Max. allowable pressure

100 °C

92 bar

74 bar

150 °C

88 bar

71 bar

200 °C

83 bar

67 bar

300 °C

72 bar

58 bar

400 °C

67 bar

54 bar

Max. allowable
operating
temperature*

Static load +400 °C

Without load +530 °C

Observe max. allowable probe temperature of the respective thermometer version.

Material

Pipe and nipple: CuZn

Capacity

Temperature

Pipe diameter

8 x 0.75 mm

10 x 0.75 mm

Max. allowable pressure

100 °C

50 bar

40 bar

150 °C

48 bar

39 bar

Max. allowable
operating
temperature*

+150 °C