31. BACKUP
Backup parameters and save them in the EEPROM memory module.
All of the configuration setting parameters can be saved in the EEPROM memory
module for backup. The backup parameters can then be restored if they have been
inadvertently changed or corrupted. Once backup is complete the EEPROM memory
module may be removed for safe storage. All DPC-12 and DPC-24 control modules
are shipped with the factory default settings saved in the EEPROM memory module.
Press EXECUTE to enter the menu.
DISABLED
This menu is disabled for inadvertent use. Proceed to enable.
ENABLED
Press and hold MENU ( ) and MENU ( ) at the same time for 4-5 seconds.
MEMCHECK
Automatically checks the EEPROM memory module for parameter type.
SURE ???
Press EXECUTE to proceed.
WAIT
Automatically begins parameter backup and generates CRC value.
VERIFY
Automatically verifies parameter backup data and CRC value.
DONE!!
Parameter backup is done and saved in the EEPROM memory module.
NO MEM!
Displayed if an EEPROM memory module is not detected.
WRONG
Displayed if the wrong type (parameter) of EEPROM memory module detected.
MEM TYPE
Displayed if the wrong type (parameter) of EEPROM memory module detected.
WRONG
Displayed if the wrong product type of EEPROM memory module detected.
PRODUCT
Displayed if the wrong product type of EEPROM memory module detected.
DATA ERR
Displayed when a data error occurs. Waits for key press to restart BACKUP.
NOTE: Be sure to BACKUP the DPC-12 or DPC-24 when installation configuration is
complete.
32. PRINTOUT
Print various system configuration settings using a hand held infrared printer.
All DPC-12 and DPC-24 control modules come equipped with an infrared (I/R) LED
that provides the ability to printout all the system configuration settings, when used
in conjunction with a hand held infrared printer (Johnson System Inc., Part Number:
JS-IP). Point the hand held printer I/R LED directly at the DPC-12 or DPC-24 control
module I/R LED within 3 ft (1m).
Press EXECUTE to enter the menu.
Press MENU ( ) to scroll through and select which item(s) to printout.
SYSTEM?
Prints general system information and configuration settings.
V-LIMIT?
Prints the output voltage limit settings for each of the 12 or 24 dimmer outputs.
CURVES?
Prints the dimmer curves for all 12 or 24 dimmer outputs.
Ø-PATCH?
Prints the phase patch for all 12 or 24 dimmer outputs.
DCPATCH?
Prints the configuration settings for the dimmer to channel patch.
SCENE>FL
Press MENU ( ) to select the desired scene (01 to 12 or 24) or all scenes (FL).
SCENE?
Prints the level settings for each dimmer output within the 12 or 24 scenes.
SCENE>01
Press EXECUTE to toggle the pointer (>) and select which scene to print.
FD-TIME?
Prints the fade time settings for each of the 12 or 24 scenes.
2 ROOM?
Prints the two room assignment for each of the 12 or 24 dimmer outputs.
ALL?
Printout all items at once.
PRINTING
Press EXECUTE on any item to begin printing.
Press ESCAPE or RESET to exit the menu.