Johnson Systems DPC-24-3000 Series Digital Pack Controller User Manual
Page 16

16
D24 Press EXECUTE to toggle the pointer (<) to select another dimmer output. Press ESCAPE to exit the menu and save the desired dimmer channel patch. Press RESET to exit the menu without saving. The menu will automatically timeout after 2 minutes of inactivity and save. 13. DIM CURV Configure the dimmer curve for each output. There are four different dimmer curve profiles that can be assigned to each individual dimmer output circuit. Square Law (SQ) curve is the industry standard and the default for all dimmers. Linear (LN) curve modifies the dimmer output for a linear relationship to the control input level. Direct Drive (DD) curve is not modified - meaning the control input level is directly proportional to the control output level. Non-Dim (ND) curve assigns the dimmer circuit to operate in a full-on or off state only, with no dimming. Dimmers set for non-dim will be triggered full-on at 55% control input and will be triggered off again at 45% control input. Press EXECUTE to enter the menu. DIM01 SQ Displays the dimmer (DIM) output (01) and its current dimmer curve. DIM24 SQ Press MENU ( ) to select the desired dimmer number from 01 to 12 or 24. DIM24 LN Press EXECUTE to toggle to linear (LN) curve mode. DIM24 DD Press EXECUTE to toggle to direct drive (DD) mode. DIM24 ND Press EXECUTE to toggle to non-dim (ND) mode. Press ESCAPE to exit the menu and save the desired dimmer curves. Press RESET to exit the menu without saving. The menu will automatically timeout after 2 minutes of inactivity and save. 14. VOUT LIM Set the maximum RMS output voltage for each dimmer. Limiting the maximum RMS voltage can greatly improve lamp life. Press EXECUTE to enter the menu. 01<127.5 Displays the dimmer (01) and its current maximum output voltage level (127.5). 24<127.5 Press MENU ( ) to select the desired dimmer number from 01 to 12 or 24. 24>127.5 Press EXECUTE to toggle the pointer (< >) to select the output voltage level. 24>100.0 Press MENU ( ) to adjust the output voltage level in 0.5 Volt increments. 24<100.0 Press EXECUTE to toggle the pointer (< >) to select another dimmer number. Press ESCAPE to exit the menu and save the desired dimmer curves. Press RESET to exit the menu without saving. The menu will automatically timeout after 2 minutes of inactivity and save. NOTE: For 240VAC operation, the maximum output voltage level is 255 and the output voltage limit is adjusted in 1 Volt increments. 15. REGULATE Configure the dimmer to channel patch for the dimmer rack. With the on-board output voltage regulation feature enabled, the maximum RMS output is limited to 118 Volts for 120VAC operation and 236 Volts for 240VAC operation. Voltage regulation automatically adjusts the internal control level to compensate for any line voltage fluctuations. ENABLED Press EXECUTE to toggle regulation from ENABLED to DISABLED. DISABLED Press EXECUTE to toggle regulation from DISABLED to ENABLED. Any change in the configuration is automatically saved. 16. STANDBY Enable or disable the power savings standby mode. When standby mode is enabled the microcontroller goes to sleep within 5 seconds of inactivity on the control inputs. The microcontroller wakes up again when a programming switch is pressed or when control is sensed on the control inputs. ENABLED Press EXECUTE to toggle standby mode from ENABLED to DISABLED. DISABLED Press EXECUTE to toggle standby mode from DISABLED to ENABLED. Any change in the configuration is automatically saved.