Quick programming reference – Johnson Systems DPC-24-3000 Series Digital Pack Controller User Manual
Page 11

11
Quick Programming Reference
to System Configuration Menu Items
Basic Menus
1. ADDRESS
Set the DMX start address.
2. DMXA-TRM
Enable or disable termination on the DMX-A input.
3. DMXB-TRM
Enable or disable termination on the DMX-B input.
Advanced Menus
4. SCENESET
Enable and setup 12 or 24 different backup scenes.
5. FADETIME
Set the fade time for each of the 12 or 24 scenes from 0 to 99 seconds.
6. SNAPSHOT
Record DMX levels into the backup scenes.
7. DIM TEST
Test the dimmer outputs one at a time, or all at once.
8. MONITOR
View the control level to each dimmer output.
9. DMX MODE
Configure the mode of the on-board DMX protocol manager.
10. 2 RM SET
Set the two room assignment for each of the dimmer outputs.
11. SH TIME
Set the DMX status hold time from 0 to 99 minutes or infinite.
12. DC PATCH
Configure the dimmer to channel patch for the dimmer pack.
13. DIM CURV
Configure the dimmer curve for each output.
14. VOUT LIM
Set the maximum RMS output voltage for each dimmer.
15. REGULATE
Enable or disable the dimmer output voltage regulation.
16. STANDBY
Enable or disable the power savings standby mode.
17. TEST INC
Set the test increment units to percent or hexadecimal.
18. L-BUTTON
Set the mode of the 12 or 24 local buttons to scene, bump or disabled.
19. Ø-PATCH
Set the zero-cross phase reference for each dimmer control output circuit.
20. V-RANGE
Set the supply voltage range for 120 Volts or 240 Volts operation.
21. LINE V
View the RMS line voltage for each power phase.
22. LINE F
View the line frequency of phase A.
23. CTL TEMP
View the temperature of the microcontroller.
24. RTIME
View the total run time of the microcontroller.
25. HARD-KEY
View the microcontroller’s unique six-character hard-key code.
26. SERIAL#
View the microcontroller’s unique six-character silicone serial number.
27. VERSION
View the microcontroller’s firmware version.
28. EEPROM
View the type of EEPROM memory module plugged in.
29. FW-LOAD
Load new firmware into the microcontroller via the EEPROM memory module.
30. RESTORE
Restore parameters saved in the EEPROM memory module.
31. BACKUP
Backup parameters and save them in the EEPROM memory module.
32. PRINTOUT
Print various system configuration settings using a hand held infrared printer.
33. DEFAULTS
Set various system configuration settings to the factory default.
34. LED INT
Set the LED intensity for the programming switches.
35. LCD VIEW