Op e n – Bryant 394HAD User Manual
Page 5
![background image](/manuals/56250/5/background.png)
—5—
6
7
8
4. Remove the furnace access door(s).
a. Upflow—remove control door. (See Fig. 9.)
b. Downflow—remove blower door after removing 2
screws first, then remove the control door. (See Fig. 10.)
Reinstall the blower door.
NOTE:
The blower door must be installed to permit furnace
operation.
9
10
5. Turn the control knob on the internal gas valve clockwise
to the indicated OFF position. Wait 5 minutes for any ex-
pelled gas to dissipate. (See Fig. 11.)
6. After waiting 5 minutes, open the external manual gas
valve. (See Fig. 12.)
7. Turn the control knob on the internal gas valve to the
PILOT position.
8. Place a lighted match or other suitable source of flame near
the top of the pilot. (See Fig. 13.)
9. Depress the button or knob and hold it down. The pilot will
light. Remove and extinguish the match while continuing
to hold the button or knob down for at least 60 sec, then
release. The pilot will remain lit.
SYSTEM
COOL OFF HEAT
FAN
AUTO ON
50
70
90
50
70
90
CL
O
S
E
11
12
13
14
NOTE:
If pilot does not stay lit, repeat steps 5 through 9; how-
ever, hold the button down for a longer period of time (at least
90 sec). If the pilot flame is extinguished after this second at-
tempt, the thermocouple should be checked for a possible mal-
function. Call your dealer for service.
10. After the pilot flame is established, turn the control knob on
the gas valve to the ON position.
11. Replace the access door. (See Fig. 15 or 16.) For down-
flow furnaces, remove the blower access door, install the
control access door, then reinstall the blower access door
and secure with 2 screws.
15
16
12. Turn on the electrical supply to the furnace.
13. Adjust the room thermostat to a setting slightly above room
temperature. This will automatically signal the furnace to
start.
14. Furnace main burners should light shortly after you set the
thermostat. After you verify that the burners are lit, you
may adjust the room thermostat to your own personal com-
fort setting. If the burners fail to light, shut down your fur-
nace and call your dealer for service. Refer to the lighting
instruction label affixed to your furnace blower access door
or page 8 for shutdown procedures.
NOTE:
To conserve energy when the heating season has ended,
you should shut down your manually ignited pilot. Follow the
procedures in the “Shutting Down Your Furnace” section of this
manual.
PILOT
OFF
ON
OP
E
N
PILOT
OFF
PILOT
OFF
ON