INSTALLATION

STEP 1: Install cold water supply fitting. Use either the included

garden hose connector or any of the other optional feed fittings.
STEP 2: Install optional drain adapter
STEP 3: Make tubing connections
STEP 4: Install RO assembly
STEP 5: Put system into operation

NOTE: Consult a licensed plumber if you are not familiar with

plumbing procedures.

Step 1: Install Cold Water Supply Fitting

A female garden hose thread connector fitting is included to be able

to hook up to a garden hose or hose bib (spigot). Keep the length

of garden hose as short as possible to minimize pressure loss. A

variety of other feed fitting and feed valves are available to be able to

connect to other existing plumbing. Check with your dealer or contact

Hydro-Logic. Comply with local plumbing codes.

WATER SUPPLY VALVE

NOTE: Be sure to turn off the water supply before installation

Cold water pipes vary in size and style. The installer will determine

type of valve that will be used. Install a valve on the cold water

supply pipe to adapt 1/2-inch OD tubing. If threaded fittings are used,

be sure to use pipe joint compound or Teflon tape on outside threads.

Turn the valve off.

Step 2: Direct black drain line to an appropriate drain

location or install optional drain adapter.

The optional 3/8” quick connect drain adapter must be installed on

the main sink drain above the P-trap. The drain adapter is designed

to fit 1-1/2-inch (3.8 cm) sink drain pipe. The black drain line may also

be directed directly into a drain point or outside. The drain water

can be re-used for a variety of applications including watering your

landscape plants, trees, shrubs and lawns. The drain (waste) water

contains the majority of the contaminants in your source (tap) water.

The PPM’s of the drain water are typically 33% higher than the

source water. A certain amount of drain water in necessary to flush

the contaminants away from the membranes and prevent them from

fouling or scaling prematurely. DO NOT restrict the black drain line.

Let it flow freely.