TROUBLESHOOTING

Issue

Possible Cause

Corrective Action

Low product flow

rate

Low driving pressure.

Increase feed pressure. Consider pump for low pressure locations.

Use short tubing runs to decrease flow restriction. Increase tubing

diameter for longer distances.

Low water temperature or high total dissolved solids (TDS).

Increase feed water temperature or feed pressure to compensate.

Plugged prefilter.

Replace plugged prefilter. Consider sediment prefilter for non-

chlorinated applications.

Scaled or fouled RO membrane.

Replace membranes.

Leak or kink in product line.

Find and repair leak or kink.

Concentrate water

runs to drain after

faucet shut off

Plugged prefilter

Replace plugged prefilter. Consider sediment prefilter for non-

chlorinated applications.

Leak in product line.

Find and repair leak. Install pressure gauge in product line to help

identify a product pressure leak.

Poor product water

quality

Water sample taken during system flush.

Take sample after three minutes of continuous operation.

Low driving pressure.

Increase feed pressure. Consider pump for low pressure locations.

Use short tubing runs to decrease flow restriction. Increase tubing

diameter for longer distances.

Plugged pre-filter.

Replace plugged prefilter. Consider sediment prefilter for non-

chlorinated applications.

Scaled, fouled, or damaged RO membrane.

Replace RO membranes.

Membrane stem o-rings damaged during installation

Replace both o-rings on membrane stem and lube properly before

installing