LOCATION OF SYSTEM

The reverse osmosis system can be installed under or near a sink or

any other water supply. The RO assembly can be placed on the sink

cabinet floor in any other location that does not apply pressure on

the disconnect elbows or tubing. A nearby suitable drain point is also

required for the drain (waste) water.

NOTE: Keep the lengths of tubing short. Longer lengths of tubing will

decrease inlet pressure and ultimately system performance.

An optional booster pump can be used on the supply line to

increase inlet pressure.

NOTE: All plumbing should be done in accordance with state and

local plumbing codes.

Some codes may require installation by a licensed plumber.

Check with the local plumbing authority prior to installation.

WARNING:

All components and tubing should be located in an

area which is not exposed to freezing temperatures.

Do not expose unit or tubing to direct sunlight.

Water Supply: To provide supply water to the RO system inlet, a

garden hose connection fitting is included with the system. Other

types of feed supply fittings are available to allow hookup to a variety

of feed sources. The feed water valve should be located as close to

the manifold assembly as possible. USE A POTABLE COLD WATER

SUPPLY ONLY. Softened water is preferred as it will extend the life

of the RO membrane elements. Other forms of pre-filtration may be

necessary depending on quality of incoming water.

THE BASIC REVERSE OSMOSIS SYSTEM cont.

Drain Point: A suitable drain point is needed for reject (waste) water

from the RO system. A floor drain, laundry tub, standpipe, sump, etc.

are all acceptable. If discharging into the utility sink or standpipe,

an air gap of greater than 1/2-inches above the flood rim must be

provided.
An optional 3/8” quick connect sink p-trap drain adapter is available

to install as an optional drain point where codes permit.
Do not connect the system drain line to the dishwasher drain or near

the garbage disposal. Back pressure from these units may cause the

air gap to overflow.

RO Manifold Assembly: The RO system can be installed in either a

horizontal or vertical orientation. Installation in the basement is also

an option. One possible location is near the laundry/ utility sink where

cold potable water and drain access are close. The location chosen

should allow adequate clearance and accessibility for membrane

element changes.