HYDAC ETS 1700 User Manual
Page 14

Safety sleeve for tank mounting the
TFP 100
Parts in contact with fluid:
All materials compatible with nickel
13. Model code
Type of sensor
0 = for PT 100 sensors
Display
Measuring range
100 = 0 .. 100 °C / 32 .. 212 °F
Modification number
000 = standard (determined by manufacturer)
0 X - 100 -
0
0 0
ETS 1 7
(Sensor TFP 100 must be ordered separately, see below)
1 = 4-digit °C
2 = 4-digit °F
14. Accessories
14.1 Accessories supplied with the unit
• PG 11 cable glands
• 4 mounting screws M5 x 20 mm
• 5-pole Binder connector, series 681
• 3 m connection line for TFP 100 (LIYCY 4x0.25 mm²)
14.2 Other accessories
(must be ordered separately)
• Temperature sensor TFP 100 (ZBE 03 plug included)
• Safety sleeve for tank mounting
• Mounting kit ( 4 vibration mounts, 4 screws M5 x 6 mm)