7. Programming enable

The unit has 2 types of programming enable which must both be set to "ON" to change the
settings. The operating programming enable can be set or removed during operation. It
provides protection from unintentional alteration. A programming disable via the main
programming enable has the effect that no change to the settings can be carried out during
operation. This serves, for example, as a safety function or as protection against
unauthorised alterations.

7.1 Altering the operating programming enable

mode

mode

3 s

pressure

3 s

press both

arrow keys

simultaneously
and hold down
for 3 s

use

or

to alter setting,

OFF

ON

= programming disabled

= programming possible

display

(release

arrow keys)

display

7.2 Altering the main programming enable

Switch off supply voltage or disconnect the unit from the supply voltage.

mode

mode

3 s

pressure

3 s

display

press both arrow

arrow keys

simultaneously

use

or

to alter setting,

OFF

ON

= programming disabled

= programming possible

(release

arrow keys)

and hold down.

down for 3 s)

voltage (hold keys

"main program state"

display

Switch on supply

Note:

If a setting has been changed "PRG" is displayed briefly when the display is switched