DensShield Tile Backer Installation Instructions
5
Tub/Shower
Sidewalls or Ceilings
Walls or Ceilings
Position DensShield
®
Tile Backer panel next to framing with the
coated (grey) face away from studs. Cut panel to required size
and make cutouts. Fit ends and edges closely.
DensShield Tile Backer may be cut by scoring and snapping with
a utility knife, working from the grey face side. Board may be
installed either parallel or perpendicular to framing for both wall
and ceiling applications.
• Steel or wood framing for walls should be spaced no greater
than 169 (406 mm) o.c. without blocking, 249 (610 mm) o.c.
with blocking when using
1
⁄
2
9
(12.7 mm) DensShield Tile
Backer, or 249 (610 mm) o.c. with
5
⁄
8
9
(15.9 mm) DensShield
®
Fireguard
®
(20 gauge [33 mils] steel studs are required for
tile applications).
Application Fastener
Min. Length Spacing
Walls &
Galvanized
69 (152 mm) o.c.
Ceilings
roofing nail
1
1
⁄
2
9
(38 mm) along framing
Walls &
Buglehead, rust
Ceilings
resistant, coarse
69 (152 mm) o.c.
(wood frame)
thread, sharp
1
1
⁄
4
9
(32 mm) along framing
point screw
Buglehead, rust
Walls &
thread, sharp
69 (152 mm) o.c.
Ceilings
point rust
1
1
⁄
4
9
(32 mm)
along framing
(metal frame) resistant drywall
screw
Floors
Galvanized
1
1
⁄
4
9
(32 mm)
89 (203 mm) o.c.
roofing nail
in both directions
Buglehead, rust
Floors
resistant, coarse
1
1
⁄
4
9
(32 mm)
89 (203 mm) o.c.
thread, sharp
in both directions
point screw
1
⁄
4
9
(6.4 mm)
29 (51 mm) o.c.
Floors
crown, corrosive
on edges/
(
1
⁄
4
9
[6.4 mm]
resistant chisel
7
⁄
8
9
(22 mm)
49 (102 mm) o.c.
only)
point staples
in field
Note: For walls, fasteners should penetrate at least
3
⁄
4
9
(19 mm) into wood
framing. Contact fastener manufacturer for proper selection of corrosion
resistance.
Fastener Guide Chart