beautypg.com

Warning, Wa rning – Gast 1HAB-25 User Manual

Page 4

background image

It is your responsibility to:
• Regularly inspect and make necessary repairs to

product in order to maintain proper operation.

• Make sure that pressure and vacuum is released

from product before starting maintenance.

MAINTENANCE

Solvent Cleaning

Use only Gast AH255B Solvent or other
non-petroleum based solvent. Do Not use kerosene
or ANY other combustible solvent to flush product.

Disconnect electrical power supply cord before
performing maintenance on this product.

If product is hard wired into system, disconnect
electrical power at the circuit breaker or fuse box
before performing maintenance on this product.

Failure to follow these instructions can result in
death, fire or electrical shock.

Electrical Shock Hazard

WARNING

Injury Hazard

Product surfaces become very hot during operation,
allow product surfaces to cool before handling.

Air stream from product may contain solid or liquid
material that can result in eye or skin damage,
wear proper eye protection.

Clean this product in a well ventilated area.

Failure to follow these instructions can result in
burns, eye injury or other serious injury.

WA

RNING

Check that all external accessories such as relief
valves and gauges are attached to cover and are not
damaged before re-operating product.

1. Remove filters and clean with Gast AH255B

solvent or other non-petroleum based solvent.

Use compressed air to dry filters and make

sure that all moisture is removed. Reinstall filters.

Check intake and exhaust filters after first 500 hours of

operation. Clean filters and determine how frequently

filters should be checked during future operation. This

one procedure will help to assure the productʼs

performance and service life.

SHUTDOWN PROCEDURES

It is your responsibility to follow proper shutdown
procedures to prevent product damage.
NEVER ADD OIL TO THIS OIL-LESS PUMP.

Proper shutdown procedures must be followed to

prevent pump damage. Failure to do so may result in

premature pump failure. Gast Manufacturing Oil-Less

Piston Vacuum Pumps and Compressors are

constructed of ferrous metals or aluminum which are

subject to rust and corrosion when pumping

condensable vapors such as water. Follow the steps

below to assure correct storage and shutdown between

operating periods.

1. Disconnect plumbing.

2. Operate product for at least five minutes without

plumbing.

3. Run at maximum vacuum for 10 to 15 minutes.

4. Repeat step 2.

5. Disconnect power supply.

6. Plug open ports to prevent dirt or other

contaminants from entering product.

Gast will NOT guarantee field-rebuilt product
performance. For performance guarantee, the
product must be returned to a Gast Authorized
Service Facility.

Service Kit contents vary. Most contain head and

cylinder gaskets, inlet and outlet valves, piston rings

and seals and a rider ring.

SERVICE KIT INSTALLATION

Disconnect electrical power supply cord before
installing Service Kit.

If product is hard wired into system, disconnect
electrical power at the circuit breaker or fuse box
before installing Service Kit.

Vent all air lines to release pressure or vacuum.

Failure to follow these instructions can result in
death, fire or electrical shock.

WARNING

Electrical Shock Hazard