TROUBLESHOOTING CHART
www.gastmfg.com
ISO 9001 & 14001 CERTIFIED
Low
High
Pump
Motor
Reason and remedy
Vacuum
Pressure
Vacuum
Pressure
Overheat
Overload
for problem.
•
•
At pump
•
•
Filter dirty.
Clean or replace.
•
At pump
•
•
Muffler dirty.
Clean or replace.
•
At pump
•
•
Vacuum line collapsed.
Repair or replace.
•
•
•
•
Relief valve set too high.
Inspect and adjust.
•
•
Relief valve set too low.
Inspect and adjust.
•
•
At pump
At pump
•
•
Plugged vacuum/pressure line.
Inspect and repair.
•
•
Vanes sticking.
Clean or replace.
•
•
Vanes worn.
Replace.
•
•
Shaft seal worn.
Replace.
•
•
•
•
Dust or offset powder in pump.
Inspect and clean.
•
•
•
Motor not wired correctly.
Check wiring diagram and line voltage.
•
•
•
•
Running at too high an RPM.
Check wiring diagram and line voltage.