Flint & Walling City Pressure Booster VP10 User Manual

Page 4

background image

4

95 North Oak Street • Kendallville, IN 46755 • © 2014 Flint & Walling, Inc. All rights reserved.

NAMEPLATE DATA

Model

VP05

VP10

HP

1/2

1

Volts

115

115

HZ/Ph

60/1

60/1

Amp

6.0

11

Amb

40C

40C

Class

B

B

Rating

Cont

Cont

LOCATION

Indoor/outdoor area – insure draining thru pressure

relief valve is available in order to avoid damage in

case of leakage.
Outdoor area – unit should be covered by a weather

proof housing, insure adequate ventilation.
FREEZING (OR REMOvING PUMP FOR

MAINTENANCE)

The pump and all piping must

be protected from freezing. If freezing weather

is forecast, and the unit will be exposed to

temperatures less than 32ºF (0ºC), remove the pump

by closing off ball valves #1 and #2, (see FIG. 1) and

removing the pump, using the union connections.

Store pump in a heated area. Open ball valve #3 to

allow city water to pass forward if desired. Insure

the piping is adequately protected from the cold

environment.
OPERATING CONDITIONS
Ambient temperature range 32ºF (0ºC) to 104ºF

(40ºC).

PRIMING
After installation (with the pump OFF), open ball

valves #1 and #2, and slowly unthread the air relief

plug (FIG 2). Allow inlet water pressure to fill the

pump cavity and remove in-line air pockets. After

the pump cavity fills with water, retighten the air relief

plug.

FIG 2 PRIMING ILLUSTRATION

a. Open ball valves #1 and #2, close 3.

d. Tighten the air

relief plug.

c. Ensure water fills

chamber from city water.

Replace plug immediately

to avoid excess moisture

on pump.

IL1207

b. Loosen the air relief plug.

#1

#2

#3

Torque : 26 in-lb

26

in-lb

If unit is shut down for extended

period of time or air enters into the system, it may be

necessary to repeat the above priming instructions to

insure the internal pump cavity is running with water

to avoid dry running damage to the internal seals.