Page 8

TROUBLESHOOTING (cont.)

PROBLEM

Equipment will not operate

Brew cycle will not start

Automatic refill will not operate af-
ter drawing hot water.

PROBABLE CAUSE

1. No power or incorrect voltage

1. No water

2. Water strainer/Flow Control

3. On/Left switch

4. Start switch

5. Brew timer

6. Relay

7. Solenoid valve

1. On/Left switch

REMEDY

(A) Plug in brewer.
(B) Check wall outlet for 120V ac
(C) Check circuit breaker/fuse.

Check plumbing and shut-off
valves.

(A) Direction of flow arrow must
be pointing towards brewer.
(B) Remove the strainer/Flow con-
trol and check for obstructions.
Clear or replace.

Refer to

Service -

On/Left switch

for testing procedures. See page
22.

Refer to

Service -

Start switch for

testing procedures. See page 26.

Refer to

Service -

Brew timer for

testing procedures. See page 16.

Refer to

Service -

Relay for test-

ing procedures. See page 23.

Refer to

Service -

Solenoid valve

for testing procedures. See page
25.

(A) The On/Left switch must be in
the upper position for the auto-
matic refill to operate.
(B) Refer to

Service -

On/Left

switch for testing procedures. See
page 22.