SERVICE (cont.)

LIMIT THERMOSTAT

Location:

The limit thermostat is located on the tank lid be-

tween the tank heater terminals.

Test Procedure:
1. Disconnect the brewer from the power source and

remove the blue wire from the limit thermostat.

2. With a voltmeter, check the voltage across the blue

wire removed from the limit thermostat and the
white wire on the tank heater terminal when the
control thermostat is turned “ON” (fully clock-
wise). Connect the brewer to the power source.
The indication must be 120 volts ac.

3. Disconnect the brewer from the power source.