Ordering information and accessories, Inspection and service – EUCHNER CES-AR-C01-AH-SA (Unicode) User Manual
Page 33
Operating Instructions Safety Switch CES-AR-C01-AH-SA
33
Ordering information and accessories
Designation
Version
Order
No.
CES-AR-C01-AH-SA
unicode
098941
Bridging plug
M12, 4-pin, plug
097645
Y-distributor
M12, 1x8-pin, 2x5-pin
097627
Y-distributor with connecting cable
M12, 1x8-pin, 2x5-pin, length 200 mm
111696
M12, 1x8-pin, 2x5-pin, length 1,000 mm
112395
Connection cable PVC 8-core,
flying lead
M12, 8-pin, 5 m
100177
M12, 8-pin, 10 m
100178
M12, 8-pin, 20 m
100179
Actuator BBA
42 mm x 25 mm
071840
Actuator BPA
40 mm x 40 mm
098775
Actuator BRN
80 mm x 40 mm
100251
Tip!
You will find further accessories, in particular for series connection, in the current
Non-Contact Safety System CES catalog at www.euchner.de.
Inspection and service
Warning!
Loss of the safety function because of damage to the system.
In case of damage, the related safety component must be replaced.
Only accessories or spare parts that can be ordered from EUCHNER may be
replaced.
Regular inspection of the following is necessary to ensure trouble-free long-term
operation:
Ì
Check the switching function (see section Functional check)
Ì
Check the secure fastening of the devices and the connections
Ì
Check for soiling
No servicing is required; repairs to the device are only allowed to be made by the
manufacturer.
Note:
The year of manufacture can be seen in the lower right corner of the rating plate.
The current version number in the format (V X.X.X) can also be found on the device.
The safety door must be re-adjusted when the device indicates that the actuator
is in the limit range.