Operating Instructions Safety Switch CES-AP-C.2-CH

17

Technical data

Note:

If a product data sheet is included with the product, the information on the data 

sheet applies in case of discrepancies with the operating instructions.

Technical data for safety switch CES-AP-CR2-CH/

CES-AP-CL2-CH

Parameter

Value

Unit

min.

typ.

max.

Housing material

Plastic PBT

Dimensions

95 x 30 x 12

mm

Weight

0.04

kg

Ambient temperature at U

B

 = 24 V DC

°C

- Plug connector with latching 

connection

- 30

-

+ 65

-  With connection cable with M12 

plug connector

  - Connection cable laid rigidly

- 40

-

+ 65

  - Connection cable movable

0

-

+ 65

Storage temperature

- 40

-

+ 70

Degree of protection

IP69K 

(IP67 for version with M12 plug connector)

Safety class

III

Degree of contamination 

3

Installation position

Any

Connection

Plug connector or connection cable

Operating voltage U

B

 (reverse polar-

ity protected, regulated, residual 

ripple < 5%)

24 ± 15% (PELV)

V DC

For the approval according to 

the following applies

Operation only with UL class 2 power supply, or equivalent 

measure

Current consumption

30

mA

Switching load according to 

DC 24 V, class 2

External fuse 

(operating voltage)

0.25

-

1.5

A

Safety outputs OA/OB

Semiconductor outputs, p-switching, short circuit-proof

- Output voltage U(OA)/U(OB) 

1)

  HIGH

U(OA)

U

B

-1.5

-

U

B

V DC

  HIGH

U(OB)

  LOW

U(OA)/U(OB)

0

1

Switching current per safety output

1

-

150

mA

Utilization category according to 

EN IEC 60947-5-2

DC-13 24 V 150 mA 

Caution: outputs must be protected with a free-wheeling diode in 

case of inductive loads.

Off-state current I

r

≤ 0.25

mA

Monitoring output OUT 

1)

Semiconductor output p-switching, short circuit-proof

- Output voltage

0.8 x U

B

-

U

B

V DC

- Max. load

-

-

50

mA

Rated insulation voltage U

i

-

-

75

V

Rated impulse withstand voltage 

U

imp

-

-

1.5

kV

Resilience to vibration

In acc. with EN IEC 60947-5-2

Switching frequency

-

-

1

Hz

Repeat accuracy R 

≤ 10

%

EMC protection requirements

In acc. with EN IEC 60947-5-3

Reliability values according to EN ISO 13849-1
Category

4

Performance Level

PL e

PFH

d

1.8 x 10

 -9

 / h

Mission time

20

years

1)  Values at a switching current of 50 mA without taking into account the cable lengths.

This manual is related to the following products: