Technical data
Note:
If a product data sheet is included with the product, the information on the data
sheet applies in case of discrepancies with the operating instructions.
Technical data for safety switch CES-AP-CR2-CH/
CES-AP-CL2-CH
Parameter
Value
Unit
min.
typ.
max.
Housing material
Plastic PBT
Dimensions
95 x 30 x 12
mm
Weight
0.04
kg
Ambient temperature at U
B
= 24 V DC
°C
- Plug connector with latching
connection
- 30
-
+ 65
- With connection cable with M12
plug connector
- Connection cable laid rigidly
- 40
-
+ 65
- Connection cable movable
0
-
+ 65
Storage temperature
- 40
-
+ 70
Degree of protection
IP69K
(IP67 for version with M12 plug connector)
Safety class
III
Degree of contamination
3
Installation position
Any
Connection
Plug connector or connection cable
Operating voltage U
B
(reverse polar-
ity protected, regulated, residual
ripple < 5%)
24 ± 15% (PELV)
V DC
For the approval according to
the following applies
Operation only with UL class 2 power supply, or equivalent
measure
Current consumption
30
mA
Switching load according to
DC 24 V, class 2
External fuse
(operating voltage)
0.25
-
1.5
A
Safety outputs OA/OB
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U(OA)/U(OB)
1)
HIGH
U(OA)
U
B
-1.5
-
U
B
V DC
HIGH
U(OB)
LOW
U(OA)/U(OB)
0
1
Switching current per safety output
1
-
150
mA
Utilization category according to
EN IEC 60947-5-2
DC-13 24 V 150 mA
Caution: outputs must be protected with a free-wheeling diode in
case of inductive loads.
Off-state current I
r
≤ 0.25
mA
Monitoring output OUT
1)
Semiconductor output p-switching, short circuit-proof
- Output voltage
0.8 x U
B
-
U
B
V DC
- Max. load
-
-
50
mA
Rated insulation voltage U
i
-
-
75
V
Rated impulse withstand voltage
U
imp
-
-
1.5
kV
Resilience to vibration
In acc. with EN IEC 60947-5-2
Switching frequency
-
-
1
Hz
Repeat accuracy R
≤ 10
%
EMC protection requirements
In acc. with EN IEC 60947-5-3
Reliability values according to EN ISO 13849-1
Category
4
Performance Level
PL e
PFH
d
1.8 x 10
-9
/ h
Mission time
20
years