Operating instructions safety switch ces-ap-c.2-ch, Connection – EUCHNER CES-AP-CL2-CH (Multicode) User Manual

Page 13

background image

Operating Instructions Safety Switch CES-AP-C.2-CH

13

Connection

Connect the device as shown in Figure 3. The OUT output can be connected to a 

control system as a monitoring output.

Important:

The subsystem CES-AP complies with PL e in accordance with EN 13849-1. To 
integrate the subsystem in a category 3 or 4 structure, it is necessary to monitor 
the downstream load (the feedback loop must be monitored).
These examples show only an excerpt that is relevant for connection of the CES 
system. The example illustrated here does not show complete system planning. 
The user is responsible for safe integration in the overall system.

GND

DC 24 V

-F1

CES-AP-C.2-...

UB
1

O

A

2

O

B

4

N

C

6

M8 plug-connector

(6-pin)

O

UT

5

0V
3

-V1

-K1

-V2

-K2

L1

M

3

~

-M1

L2

L3

Fig. 3: Connection example CES-AP-CR2-CH/CES-AP-CL2-CH