2.02

A.

Panel System shall be the Englert Series 2000, 1-3/4” high, 18” wide, Structural Standing Seam Snap-Lock System,
(with pencil ribs, optional) with sealant applied at the panel interlock specify “with battens” if you wish a batten
appearance. The panels shall have baked on finish as specified in Section 2.05 hereunder, in Manufacturer’s
standard colors. Manufacturer shall offer at least a minimum of 23 standard colors to choose from.

B.

Substrate:

 24 Gauge baked on finish over Galvalume ASTM A-792-83, AZ55, 50 KSI yield point, 52 KSI tensile

strength

 * 22 Gauge baked on finish over Galvalume per ASTM A-792-83, AZ50, 50 KSI yield point, 52 KSI

tensile strength.

 * .032” or .040” Aluminum Alloy 3105-H14 approved equal.

NOTE TO SPECIFIER: *22 gauge steel and .032” and .040” aluminum are available subject to
minimum order requirements. Call Englert for details.

C.

Performance:

1. Panel shall meet the requirements of Underwriter’s Laboratories, Inc. for Class 90 wind uplift resistance.
2. Air Infiltration: No greater than 0.014 CFM/Ft2 at a test pressure of 1.57 PSF and 0.009 CFM/Ft2 at a test

pressure of 6.24 PSF per ASTM E-283-73.

3. Water Resistance: When tested for 5 gallons per minute spray for 15 minutes duration at each test pressure of

1.57 PSF, 6.24 PSF, 12.5 PSF, and 15.1 PSF, there shall be no evidence of water penetration, per ASTM E-
331-70.

4. Panel shall display a flame spread classification of a Class 1 when tested in accordance with ASTM E-84-87.
5. Panel shall be tested and conform to the requirements of the modified ASTM E-330 static pressure differential

test.

6. Panel shall be tested and conform to the requirements of the Dade County Florida non-structural roofing

system criteria, product approval number must be supplied for record.

7. Panel shall be tested and conform to requirements of the ASTM E1592 wind up-lift criteria.
8. Panel system shall be tested in accordance with ASTM E-1680-95 standard test method for rate of air leakage

through exterior metal roof panel systems.

9. Panel system shall be tested in accordance with ASTM E-1646-95 standard test method for water penetration

of metal roof panel system by uniform static air pressure difference.

IF METAL SOFFIT IS REQUIRED, , SPECIFY AS FOLLOWS:

2.03 SOFFIT PANEL SYSTEMS

A.

Soffit Panels: Series 2000, 18” wide flat panels, all fasteners shall be concealed, and panels shall give a flush
appearance, with pencil ribs, optional. The soffit panels shall have the same finish as the roofing system.

B.

Substrate:

 24 Gauge baked on finish over Galvalume ASTM A-792-83, AZ55, 50 KSI yield point, 52 KSI tensile

strength

 * 22 Gauge baked on finish over Galvalume per ASTM A-792-83, AZ55, 40 KSI yield point, 52 KSI tensile

strength.

 * .032” or .040” Aluminum Alloy 3105-H14 approved equal.

NOTE TO SPECIFIER: *22 gauge steel and .032” and .040” aluminum are available subject to minimum
order requirements. Call Englert for details.

2.04 FABRICATION

A.

Panel Construction: Panels shall be uniformly dimensioned, rollformed to exact lengths to avoid trimming. The
panel system shall be anchored as recommended by the Manufacturer. All fasteners shall be concealed. Panels shall
be continuous from ridge to eaves with no end laps. There shall be no face penetration of panels, except as approved
by the architect for securing panels to facilitate directional expansion/contraction.

B.

Flashing and Trim: All exposed standard or special flashing/trim and such other brakeformed in the same gauge,
color, and finish to match roofing panels, furnished with protective strippable film to be removed upon installation.

C.

Accessories such as clips, closures, fasteners, etc., shall be as recommended by the Manufacturer.