Dimensions: specifi cations – Enerpac DGR-Series User Manual
Page 15
![background image](/manuals/558479/15/background.png)
15
7.0 TECHNICAL DATA - MODEL DGR-2 DIGITAL PRESSURE GAUGE
Dimensions:
Specifi cations:
Environmental Specifi cations
Acceptable Range
Ambient Operating
Temperature
4ºF to 140ºF
[-20ºC to 60ºC]
Hydraulic Oil
Temperature
4ºF to 176ºF
[-20ºC to 80ºC]
Storage Temperature
(batteries installed)
4ºF to 140ºF
[-20ºC to 60ºC]
Storage Temperature
(batteries removed)
4ºF to 176ºF
[-20ºC to 80ºC]
Temperature Coeffi
cient
0.04%/ºF [-20ºC to 180ºC]
zero and span, reference temp. 70ºF
Maximum Pressure Rating
Accuracy
Update
Rate
Power
Req’d
Weight
Hydraulic
Connection
Enclosure
Rating
psi
bar
mPa
kg/cm
2
0.25%
250ms
500ms
1s
(user-
selectable)
3 VDC
(two AA
alkaline
batteries)
lbs
kg
1/4 inch NPTF
Male
IP67
20000
1380
140
1400
0.5
0,23
WARNING: Never exceed
maximum pressure rating.
Range & Interval Information
Unit of
Measure
Selected
Range
Interval
psi
0-20000
1
bar
0-1380
0.1
mPa
0-140
0.01
kg/cm
2
0-1400
0.1
Agency Approvals
CE EN 61326 (1998)
CE EN 61326 Annex A (heavy industrial)
UL/cUL-61010-1 (pending)
RoHS compliant
This device conforms with the
requirements for CE Marking.
2.64 inch
67 mm
1.99 inch
50,5 mm
Ø 3.08 inch
78,13 mm
2.02 inch
51,3 mm
1.063 inch
27 mm Hex
1/4 inch NPTF Male
0.69 inch
17,5 mm
Replacement
Protective Boot
Order Enerpac
Part No. DGB-2
◃