beautypg.com

Chapter 6: wiring, Chapter 6, Wiring – ElmoMC Gold Line Digital Servo Drives-Gold DC Bell User Manual

Page 19: N chapter 6: wiring

background image

Gold DC Bell Installation Guide

MAN-G-DCBELIG-EC (Ver. 1.200)

||The Gold DC Bell Connection Diagram|

www.elmomc.com

19

Table of Contents

Chapter 6:

Wiring

Once the product is mounted, you are ready to wire the device. Proper wiring, grounding and
shielding are essential for ensuring safe, immune and optimal servo performance of the drive.

The following table legend describes the wiring symbols detailed in all installation guides.

Wiring Symbol

Description

Earth connection (PE)

Protective Earth Connection

Common at the Controller

Shielded cable with drain wire.
The drain wire is a non-insulated

wire that is in direct contact with the

braid (shielding).
Shielded cable with drain wire

significantly simplifies the wiring and

earthing.

Shielded cable braid only, without

drain wire.

Twisted-pair wires

Encoder Earthing.
The cable`s shield is connected to the

chassis (PE) in the connector.
Earthing the Encoder and connecting

the Earth (PE) to the drive COMRET is

mandatory to insure reliable

operation, high noise immunity and

rejection of voltage common mode

interferences.