beautypg.com

DIGIWEIGH DWP-500C2X User Manual

Page 4

background image

3

Press[lb/kg]key,kg,lb switch。

Basic weight unit is kg.

5. Auto backlight, when weight change, auto backlight open, when stable, auto

backlight close.

6. Press[lb/kg]key 1.5 second,backlight by manual.

7. Auto power off. When scale is stable, 5 mins.later, power off automatically.

Socket illustrate

1. CN1 :load cell socket

⑴:+E

⑵:+S

⑶ –S

⑷ -E

⑸GND

2. CN2: power socket

⑴+6V(recommend 6V/1.3Ah Lead Acid batteries)

⑵GND

3. CN3:keyboard socket

⑴kg/lb key

⑵ZERO key

⑶ON/OFF key

⑷GND