Troubleshooting guide 3 – Condux WDR505 Underground Pulling Trailer User Manual
Page 17

17
Troubleshooting Guide
3.
7.
PROBLEM:
CAUSE:
SOLUTION:
The diesel engine starter
doesn’t work.
Burned fuse
Replace
Ran down battery
Recharge or replace
Disconnected contacts of the
ignition system / starter
Reconnect
Oxidised contacts of the
ignition system / starter
Clean or spray with a
suitable vaporiser
Starter out of order
Replace / Technical
assistance
Diesel engine doesn’t
work.
The emergency push-
button is pushed in locked
position
Release
The ignition push-button is
not pushed
Push the ignition push-
button and keep it
pushed till the engine
starts
The pre-heating glow plugs
warning light isn’t turned off
Wait for the turning off
of the pre-heating glow
plugs warning light
Fuel problem
Check the fuel level in
the tank
Check the fuel filter
Diesel engine turns
off when releasing the
ignition push-button.
Check of the engine oil
pressure
Add engine oil
Defective sensor–
check contacts /
replace
Engine anomaly –
technical assistance
Check of the engine cooling
liquid temperature
Add cooling liquid
Defective sensor–
check contacts /
replace
Engine anomaly –
technical assistance
The feeding pressure
is lower than 24 bar
– 340psi
Clogged hydraulic oil filter
Replace
Defective pump
Technical assistance
Diesel engine doesn’t
increase rpm
Disconnected accelerator
cable
Verify and if necessary
replace