Condux Extension Frame User Manual
Page 7

7
F. CONNECT USING CENTER JOINT
If applicable, the
Center Joint can be adjusted to match Extension Frame configuration
and is secured with locking pins. The 2" Sch 40 GRC steel duct from the Duct End Joint
and from Cable Puller Adapter connects to the Extension Frame Center Joint in the
cylindrical duct ports and is locked in place by tightening the cap screws and lock nuts
(Figure 11).
NOTE: When Center Joint is not needed, 2" Sch 40 GRC steel duct from Duct
End Joint connects directly to Cable Puller Adapter in the cylindrical duct ports
and is locked in place by tightening the cap screws and lock nuts (Figure 12).
G. THREAD CABLE PULLING ROPE
Pulling rope must be thread from the conduit across all sheaves on the Extension Frame
and through the CableGlider Cable Puller (Figure 13). Please refer to CableGlider Cable
Puller manual for proper Cable Puller set up.
!WARNING: Pulling rope must contact ALL sheaves on frame and
puller when threading. Puller frame will bend and break causing
serious personal injury or death if not threaded properly.
H. ENSURE CONFIGURATION INTEGRITY/STABILITY
Make sure that all cap screws, thumb screws and lock nuts are secure. Make sure all lock-
ing pins are in place. Make sure all connections are made properly.
I. OPERATE CAREFULLY
Operate CableGlider Cable Puller as per Cable Puller manual.
Figure 12
Figure 13