Ft sb 11 18 – Comelit FT SB 11 User Manual
Page 20
GROUP S.P.A.
FT SB 11
18
INITIAL CONDITION
5E) READING THE STORED LIST ( UPLOAD )
By means of the software art.1249/A it is possible to read the list with the User name and
Code fields from module 3072/A. It is necessary to carry out the following operations:
Module supplied in
stand-by condition.
SELECT NAME
BY
↑
↓
SELECT NAME
BY
SELECT NAME
BY
UPLOAD
ENDED
Or:
UPLOAD
FAILED
↑
↓
↑
↓
If the upload has
terminated successfully.
If some anomaly
has occurred during
the upload of the list.
ON DISPLAY
DESCRIPTION
OPERATION
Connect the small cable
provided with the software
art.1249/A to terminals
TX / RX / - ( or D / D-
if there is an RS485 line.
Ref. wiring diagram
CA/EN/109 page 34).
Run the software art. 1249/A.
Consult the in-line Guide
for the settings required.
Press the Upload
pushbutton in the
software art.1249/A.
The list will be loaded
in software art.1249/A.
10 = DEFAULT
0 =
Connection by means
of RS232 line
0
180
01
10
POSSIBILE VALUE
DEFAULT VALUE
PARAMETER
1=ITALIAN
2=ENGLISH
3=FRENCH
4=GERMAN
5=PORTUGUESE
6=DANISH
7=FINNISH
8=DUTCH
9=SPANISH
10=DEFAULT
(you will be requested to enter
the language the next time
module 3072/A is turned on).
0 = Connection by means
of RS232 line
1 = Connection by means
of RS485 line
Value from 01 to 255
Value from 10 to 180. It
expresses the time in seconds
of the entry phone conversation.
Value from 01 to 99. It
expresses the time in seconds
of the door-opening relay.
Value from 0 to 10.
It expresses the time in
seconds of the reset wait
at the end of a telephone
conversation.
LANGUAGE
DOWNLOAD TYPE
ADDRESS RS485
AUDIO TIMING
DOOR LOCK TIME
RESET TIME
6) PARAMETER TABLE
The explanatory table of the configuration parameters of module art.3072/A is given below: