FT SB 11
12
GROUP S.P.A.
It is possible to modify
the conversation time,
the door-opening relay
activation time and the
reset wait time.
Continual pressure on
the
▲ or ▼ key increases
or decreases the value
by steps of 10.
If the entry has been made
correctly.
ON DISPLAY
DESCRIPTION
OPERATION
Select by means of the
▲ or ▼ keys the
MAIN SETTINGS /
SYSTEM PARAM /
SPEAKER PARAM. menu.
Scroll the menu items
by means of the
▲ or ▼
keys and select the one
regarding the parameter
to be modified.
EXAMPLE: Modifying the
conversation time.
Enter the desired value
using the
▲ or ▼ keys.
EXAMPLE: 100
Press the
key to confirm
the parameter value.
After the modification has
been made, remove the
connections between PR
and – on the 3072/A 3062
3262 and 3268 terminals.
SPEAKER PARAM.
ENTER t AUDIO
ENTER t AUDIO
VALUE: _ _ _
ENTER t AUDIO
VALUE: 100
PARAMETER
CHANGED
↑
↓
↑
↓
↓
INITIAL CONDITION
4) SETTINGS
4A) SYSTEM PARAMETERS
4A-1) MODIFYING THE CONVERSATION, DOOR-OPENING AND PORTER MODULE
RESET TIME PARAMETERS
This operation allows the conversation, door-opening relay closing and reset wait times of
the porter module to be modified.
Module art. 3072/A
supplied with terminal
PR connected to terminal -.
Porter module art. 3062 / 3262/
3268 supplied with terminal
PR connected to terminal -.
MAIN
SETTINGS
↓
The module is in the
programming stage:
▲ or ▼ to scroll the menus
to select the menu
to pass to the lower
level menu.
The porter module is in the
programming stage.
INITIAL CONDITION
3C) CANCELLING A CALL
Call sent or conversation
in progress.
Module Art. 3072/A returns
to the stand-by state and
the call sent on the riser
is cancelled.
ON DISPLAY
DESCRIPTION
OPERATION
Press the
key.
CALL
EFFECTED
or
COMMUNICATING…
SELECT NAME
BY
or
SEARCH THE