Comelit MT 8171IGK User Manual
Page 16
16
16
EN
S1-5
S1-4
S1-3
S1-2
S1-1
12345678
Art. 4878K
Art. 4879K
2
Art. 4879K
Additional main or secondary monitors
The setting of JP1 defines whether the bracket in question will be managed
as main (M) or secondary (S).
The external unit can manage up to a maximum of 3 door entry monitors
or door-entry phones for each call button.
In the classic Genius Kit configuration, it is therefore possible to have at
most 2 secondary door entry monitors and 1 main door entry monitor for
each call button, all powered by the same Art. 1207.
It is possible to manage up to 3 main door entry monitors within the same
family unit (i.e. set to the same user code). In this particular configuration,
the additional main door entry monitors must each be powered by the
special Art. 1212/B (see variant GK/HI and GK/AABI, page 64, 65).
When a call is made from the external unit, the monitor switched on will be
the main door entry monitor.
Any secondary monitors in the same residence unit will remain off.
When responding to a call from the external unit using a secondary door
entry monitor, the image is automatically displayed on the monitor.
At this point, the main door entry monitor switches off and the image
appears on the door entry monitor on which button 2 - video request - was
pressed.
To display the image without lifting the handset, press button 2 - video
request.
Setting bracket Art. 5814K as main or secondary
Main
Secondary
Description of button functions
Actuator
Pressing the button 1 set to Actuator mode allows activation of Art. 1256,
which can be used to open gates, up&over doors, etc., or to activate the
cyclic camera module Art. 1259/A.
Self-ignition/Video request
√ Self-ignition is possible only when the system is in standby
√ Self-ignition is recommended only for systems with 1 or 2 entrances
Press button 2 in this mode to display the image transmitted by the
external unit on the monitor, even if no call has been made.
In systems with 2 external units, it is possible to view the image from one
EXTERNALæUNITæORæTHEæOTHERæALTERNATELYæhTOGGLEvæFUNCTION æBYæPRESSINGæBUTTONæ
2.
On secondary monitors (JP1 in position S), button 2 has the video request
function and can be used to switch on a monitor on receipt of a call from
the external unit.
Ignition:
Ź press and immediately release the specific button (button 2 - if the
factory settings have been retained)
Description of button functions and settings
Settings for bracket Art. 5814K and Style door-entry phone Art. 2608
Position of the microswitches for bracket Art. 5814K and door-entry phone
Code
S1
1
2
Ź Art. 2608, Art. 2610, Art. 2628: the values of S1
define the call address of the door-entry phones as
shown in the table below.
Ź In a GENIUS KIT system it is possible to set MAX two user addresses
address 1
address 2